Our experts are working hard on our CDCS exam questions to perfect every detail in our research center. Once they find it possible to optimize the CDCS study guide, they will test it for many times to ensure the stability and compatibility. Under a series of strict test, the updated version of our CDCS learning quiz will be soon delivered to every customer’s email box since we offer one year free updates so you can get the new updates for free after your purchase.
EXIN CDCS Exam Syllabus Topics:
Topic | Details |
---|---|
Topic 1 |
|
Topic 2 |
|
Topic 3 |
|
CDCS Valid Test Simulator | New CDCS Real Test
Exam4PDF is also offering one year free CDCS updates. You can update your CDCS study material for 90 days from the date of purchase. The EXIN EPI Certified Data Centre Specialist updated package will include all the past questions from the past papers. You can pass the CDCS exam easily with the help of the PDF dumps included in the package. It will have all the questions that you should cover for the EXIN CDCS Exam. If you are facing any issues with the products you have, then you can always contact our 24/7 support to get assistance.
EXIN EPI Certified Data Centre Specialist Sample Questions (Q42-Q47):
NEW QUESTION # 42
Smoke sensors need to be tested to ensure that they pick up a potential fire in the data center.
What should you recommend?
- A. Inject smoke at the floor level
- B. Test the sensors according to the vendor specification
- C. Press the self-test button on each sensor in the data center
- D. Test the sensors by injecting smoke or simulated smoke directly into the sensor
Answer: B
Explanation:
Testing smoke sensors should be conducted according to the vendor specifications to ensure compliance with safety standards and accurate results. Vendors provide specific testing procedures to account for the sensor type, environment, and operational characteristics, ensuring that tests do not damage the equipment or provide false results.
Detailed Explanation:
Smoke sensors can vary by type and sensitivity, so following the vendor's recommended testing procedure ensures the sensors function correctly without risking sensor damage. Injecting smoke or using a self-test might be insufficient or could lead to inaccurate assessments if they do not align with the vendor's testing protocol.
EPI Data Center Specialist References:
EPI recommends adhering to manufacturer specifications for testing critical safety equipment, ensuring that tests reflect real-world conditions without compromising sensor integrity or reliability.
NEW QUESTION # 43
In which stage of the data center life cycle does commissioning take place?
- A. Retire
- B. Design
- C. Operate/optimize
- D. Implement
Answer: D
Explanation:
Commissioning occurs during the Implementation stage of the data center life cycle. This phase involves the final testing and verification of systems and equipment to ensure they meet design specifications and operational requirements before the data center goes live.
Detailed Explanation:
The Implement phase includes activities such as installation, configuration, and testing. Commissioning is a crucial step that validates the performance and reliability of all critical systems, including power, cooling, and network infrastructure, to ensure they operate as intended under various conditions. Proper commissioning helps identify and resolve any issues before the data center becomes fully operational.
EPI Data Center Specialist References:
EPI training emphasizes that commissioning is essential for verifying that the data center meets design and performance criteria, aligning with best practices in data center project management to minimize risks and ensure readiness for operation.
NEW QUESTION # 44
The 'maximum exposed area' of the fire-rated glass is defined by the supplier as 3 sqm/32 sqft. The window area is 4 sqm/43 sqft.
What would be the best option?
- A. Do not use fire-rated glass due to the size limit and replace it with normal glass.
- B. Split the window in two equal parts using an aluminum frame.
- C. Split the window into parts smaller than specified as the maximum exposed area and ensure fire-rated frames are used.
- D. Split the window in two equal parts fitted together with transparent silicon glue.
Answer: C
Explanation:
When the window area exceeds the maximum exposed area specified for fire-rated glass, it is necessary to split the window into sections that comply with the fire rating requirements. This means creating smaller sections that are each within the 3 sqm/32 sqft limit and using fire-rated frames to ensure that the entire assembly meets fire safety standards. This approach maintains the fire-rated integrity of the glass, while allowing for larger window areas.
Detailed Explanation:
Fire-rated glass is designed to contain fire and prevent it from spreading. If the window exceeds the maximum exposed area defined by the supplier, the integrity of the fire-rated glass could be compromised. By dividing the window into compliant sections with fire-rated frames, you ensure that each pane performs as intended in the event of a fire. Fire-rated frames help maintain the fire resistance across the entire assembly, making this option the best for safety and compliance.
EPI Data Center Specialist References:
EPI recommends adhering strictly to fire safety standards, especially when using materials like fire-rated glass. The guidelines emphasize that modifications should always respect the manufacturer's specifications to ensure the system remains effective in containing and preventing the spread of fire.
NEW QUESTION # 45
What is a potential disadvantage of using water mist as a fire extinguishing system?
- A. It will rapidly increase the humidity level in the data center, which can cause a potential risk for the operation of the equipment
- B. It extracts oxygen from the air creating a potential risk for humans inside the computer room
- C. It has droplets that are too small (100-120 microns) so it can only be used for small fires
- D. It only uses 10% of the water normally used in a water-based fire suppression, which might not be enough to suppress the fire
Answer: A
Explanation:
A potential disadvantage of using a water mist fire suppression system is that it can rapidly increase the humidity within the data center, which may pose risks to sensitive electronic equipment. Excessive humidity can lead to condensation, which could damage electronics and lead to short circuits or corrosion over time.
Detailed Explanation:
Water mist systems use fine droplets to suppress fires by cooling and displacing heat. However, the moisture generated may raise the humidity level to the point where it exceeds safe operational limits for IT equipment. Therefore, while water mist systems are effective in fire suppression, they may not be ideal in environments where high humidity could damage sensitive equipment.
EPI Data Center Specialist References:
EPI guidelines advise considering the impact of humidity from fire suppression systems, particularly in environments housing electronic equipment. It's essential to weigh the benefits of fire suppression against potential risks to operational equipment when choosing suppression methods.
NEW QUESTION # 46
The building in which the computer room is housed is required to have a sprinkler system. The building is therefore equipped with a wet pipe system.
What action, if any, should you recommend for the computer room?
- A. Replace the wet pipe system with a deluge system.
- B. Maintain the current wet pipe system.
- C. Replace the wet pipe system with a dry pipe system.
- D. Replace the wet pipe system with a pre-action system.
Answer: D
Explanation:
In computer rooms, replacing a wet pipe system with a pre-action system is advisable. Pre-action systems provide additional protection by requiring two triggers (e.g., heat and smoke) before water is released, minimizing the risk of accidental discharge and water damage, which is crucial for safeguarding sensitive IT equipment.
Detailed Explanation:
Wet pipe systems contain water in the pipes at all times, which poses a higher risk of accidental discharge. Pre-action systems, however, only fill the pipes with water upon detection of a fire, reducing the risk of water-related damage due to leaks or malfunctions. This approach is considered best practice for environments housing sensitive electronic equipment.
EPI Data Center Specialist References:
EPI advises using pre-action fire suppression in data centers to reduce risks associated with accidental water release, providing a safer and more controlled fire response that better protects critical infrastructure.
NEW QUESTION # 47
......
Exam4PDF alerts you that the syllabus of the EXIN EPI Certified Data Centre Specialist (CDCS) certification exam changes from time to time. Therefore, keep checking the fresh updates released by the EXIN. It will save you from the unnecessary mental hassle of wasting your valuable money and time. Exam4PDF announces another remarkable feature to its users by giving them the EXIN EPI Certified Data Centre Specialist (CDCS) dumps updates until 1 year after purchasing the EXIN EPI Certified Data Centre Specialist (CDCS) certification exam pdf questions.
CDCS Valid Test Simulator: https://www.exam4pdf.com/CDCS-dumps-torrent.html
- CDCS Pdf Pass Leader ???? CDCS Exam Discount Voucher ???? Reliable CDCS Braindumps Sheet ???? Open ➽ www.actual4labs.com ???? enter ➥ CDCS ???? and obtain a free download ????CDCS Dumps Discount
- 2025 Useful CDCS: EXIN EPI Certified Data Centre Specialist Reliable Test Pdf ???? Search for ➽ CDCS ???? and download it for free immediately on “ www.pdfvce.com ” ➿CDCS Dumps Cost
- CDCS Simulations Pdf ???? CDCS Discount ???? CDCS Simulations Pdf ➡ Search for ▶ CDCS ◀ and obtain a free download on ▷ www.pass4leader.com ◁ ????New CDCS Dumps Files
- CDCS Reliable Test Pdf - Pass Guaranteed Quiz 2025 CDCS: First-grade EXIN EPI Certified Data Centre Specialist Valid Test Simulator ???? Enter “ www.pdfvce.com ” and search for { CDCS } to download for free ????CDCS Simulations Pdf
- CDCS Free Updates ???? CDCS Test Simulator Fee ???? CDCS Exam Blueprint ???? The page for free download of ⮆ CDCS ⮄ on ⇛ www.real4dumps.com ⇚ will open immediately ????Valid CDCS Mock Exam
- CDCS Reliable Test Vce ⚫ CDCS Pdf Pass Leader ???? CDCS Simulations Pdf ???? Download [ CDCS ] for free by simply searching on ⇛ www.pdfvce.com ⇚ ????CDCS Simulations Pdf
- CDCS Discount ???? CDCS Pdf Pass Leader ???? CDCS Dumps Discount ???? Search for ➤ CDCS ⮘ and easily obtain a free download on ⇛ www.prep4pass.com ⇚ ????CDCS Exam Discount Voucher
- CDCS Exam Blueprint ???? CDCS Test Simulator Fee ???? CDCS Simulations Pdf ???? Search for ▷ CDCS ◁ and download it for free immediately on ▛ www.pdfvce.com ▟ ????Test CDCS Score Report
- Unlock Your Potential with EXIN CDCS Exam Questions ???? Easily obtain [ CDCS ] for free download through ✔ www.pass4test.com ️✔️ ????CDCS Exam Blueprint
- CDCS Mock Test ???? CDCS Mock Test ???? Valid CDCS Test Book ???? The page for free download of { CDCS } on ⮆ www.pdfvce.com ⮄ will open immediately ????CDCS Dumps Cost
- CDCS Valid Exam Format ???? CDCS Simulations Pdf ???? CDCS Free Updates ???? Enter ⏩ www.exam4pdf.com ⏪ and search for { CDCS } to download for free ????Valid CDCS Mock Exam
- CDCS Exam Questions
- know2succeed.com theduocean.org ilearn.bragone.it www.surfwebhub.com experienceletterzone.com associates.gmdf.or.tz iibat-academy.com ngeehub.com beyzo.eu appos-wp.edalytics.com